东莞市裕升高分子材料有限公司
VALOX? Resin VX4930 - Europe
Polybutylene Terephthalate
Product Description:
VALOX VX4930 is a 30% glass reinforced nucleated PBT/ASA blend with excellent mechanical properties, high dimensional stability and low density. Applications: connectors and automotive industry.
General | |
Material Status
|
|
UL Yellow Card1
|
|
Search for UL Yellow Card
|
|
Availability
|
|
Filler / Reinforcement
|
|
Additive
|
|
Features
|
|
Uses
|
|
RoHS Compliance
|
|
Processing Method
|
Physical |
Nominal Value
|
Unit
|
Test Method
|
Density / Specific Gravity
|
1.46
|
g/cm3
|
ASTM D792,ISO 1183 |
Melt Mass-Flow Rate (MFR)
|
ASTM D1238 | ||
200°C/3.8 kg
|
13
|
g/10 min
|
|
265°C/5.0 kg
|
35
|
g/10 min
|
|
266°C/5.0 kg
|
35
|
g/10 min
|
|
Melt Volume-Flow Rate (MVR)
|
ISO 1133 | ||
250°C/5.0 kg
|
13
|
cm3/10min
|
|
265°C/5.0 kg
|
25
|
cm3/10min
|
|
Molding Shrinkage
|
Internal Method | ||
Across Flow2
|
0.30 to 0.70
|
%
|
|
Flow2
|
0.10 to 0.30
|
%
|
|
Flow : 3.20 mm
|
0.30 to 0.70
|
%
|
|
Water Absorption
|
ISO 62 | ||
Saturation, 23°C
|
0.71
|
%
|
|
Equilibrium, 23°C, 50% RH
|
0.23
|
%
|
|
Hardness |
Nominal Value
|
Unit
|
Test Method
|
Rockwell Hardness (R-Scale)
|
116
|
ISO 2039-2 | |
Ball Indentation Hardness (H 358/30)
|
210
|
MPa
|
ISO 2039-1 |
Mechanical |
Nominal Value
|
Unit
|
Test Method
|
Tensile Modulus
|
|||
--3
|
9500
|
MPa
|
ASTM D638 |
--
|
9600
|
MPa
|
ISO 527-2/1 |
Tensile Strength
|
|||
Yield4
|
125
|
MPa
|
ASTM D638 |
Yield
|
130
|
MPa
|
ISO 527-2/5 |
Break4
|
125
|
MPa
|
ASTM D638 |
Break
|
130
|
MPa
|
ISO 527-2/5 |
Tensile Elongation
|
|||
Yield4
|
2.8
|
%
|
ASTM D638 |
Yield
|
2.8
|
%
|
ISO 527-2/5 |
Break4
|
2.8
|
%
|
ASTM D638 |
Break
|
2.8
|
%
|
ISO 527-2/5 |
Flexural Modulus
|
|||
50.0 mm Span5
|
7700
|
MPa
|
ASTM D790 |
--6
|
8200
|
MPa
|
ISO 178 |
Flexural Stress
|
|||
--6,7
|
185
|
MPa
|
ISO 178 |
--6,8
|
180
|
MPa
|
ISO 178 |
Yield, 50.0 mm Span5
|
175
|
MPa
|
ASTM D790 |
Flexural Strain - at Break9
|
2.9
|
%
|
ISO 178 |
Taber Abrasion Resistance (1000 Cycles, 1000 g, CS-17 Wheel)
|
65.0
|
mg
|
Internal Method |
Impact |
Nominal Value
|
Unit
|
Test Method
|
Charpy Notched Impact Strength
|
|||
-30°C10
|
6.0
|
kJ/m2
|
ISO 179/1eA |
-30°C
|
9.0
|
kJ/m2
|
ISO 179/2C |
23°C10
|
7.0
|
kJ/m2
|
ISO 179/1eA |
23°C
|
9.0
|
kJ/m2
|
ISO 179/2C |
Charpy Unnotched Impact Strength
|
|||
-30°C10
|
25
|
kJ/m2
|
ISO 179/1eU |
-30°C
|
45
|
kJ/m2
|
ISO 179/2U |
23°C10
|
30
|
kJ/m2
|
ISO 179/1eU |
23°C
|
55
|
kJ/m2
|
ISO 179/2U |
Notched Izod Impact
|
|||
-30°C
|
80
|
J/m
|
ASTM D256 |
0°C
|
80
|
J/m
|
ASTM D256 |
23°C
|
80
|
J/m
|
ASTM D256 |
-30°C11
|
8.0
|
kJ/m2
|
ISO 180/1A |
0°C11
|
8.0
|
kJ/m2
|
ISO 180/1A |
23°C11
|
9.0
|
kJ/m2
|
ISO 180/1A |
Unnotched Izod Impact
|
|||
-30°C
|
800
|
J/m
|
ASTM D4812 |
23°C
|
800
|
J/m
|
ASTM D4812 |
-30°C11
|
45
|
kJ/m2
|
ISO 180/1U |
23°C11
|
50
|
kJ/m2
|
ISO 180/1U |
Instrumented Dart Impact (23°C, Total Energy)
|
78.0
|
J
|
ASTM D3763 |
Thermal |
Nominal Value
|
Unit
|
Test Method
|
Heat Deflection Temperature
|
|||
0.45 MPa, Unannealed, 4.00 mm, 100 mm Span12
|
215
|
°C
|
ISO 75-2/Be |
1.8 MPa, Unannealed, 3.20 mm
|
190
|
°C
|
ASTM D648 |
1.8 MPa, Unannealed, 4.00 mm, 100 mm Span12
|
190
|
°C
|
ISO 75-2/Ae |
Vicat Softening Temperature
|
|||
--
|
218
|
°C
|
ASTM D152513,ISO 306/A5013 |
--
|
182
|
°C
|
ASTM D152514,ISO 306/B120,ISO 306/B50 |
Ball Pressure Test (123 to 127°C)
|
Pass
|
IEC 60695-10-2 | |
CLTE
|
|||
Flow : -40 to 40°C
|
2.2E-5
|
cm/cm/°C
|
ASTM E831 |
Flow : 23 to 60°C
|
2.2E-5
|
cm/cm/°C
|
ISO 11359-2 |
Transverse : -40 to 40°C
|
1.2E-4
|
cm/cm/°C
|
ASTM E831 |
Transverse : 23 to 60°C
|
1.2E-4
|
cm/cm/°C
|
ISO 11359-2 |
Thermal Conductivity
|
0.26
|
W/m/K
|
ISO 8302 |
RTI Elec
|
50.0
|
°C
|
UL 746 |
RTI Imp
|
50.0
|
°C
|
UL 746 |
RTI Str
|
50.0
|
°C
|
UL 746 |
Electrical |
Nominal Value
|
Unit
|
Test Method
|
Surface Resistivity
|
1.0E 15
|
ohms
|
IEC 60093 |
Volume Resistivity
|
1.0E 15
|
ohms·cm
|
IEC 60093 |
Electric Strength (3.20 mm, in Oil)
|
21
|
kV/mm
|
IEC 60243-1 |
Relative Permittivity
|
IEC 60250 | ||
50 Hz
|
3.60
|
||
60 Hz
|
3.60
|
||
1 MHz
|
3.20
|
||
Dissipation Factor
|
IEC 60250 | ||
50 Hz
|
2.4E-3
|
||
60 Hz
|
2.4E-3
|
||
1 MHz
|
0.018
|
||
Comparative Tracking Index (CTI)
|
PLC 1
|
UL 746 | |
Comparative Tracking Index
|
500
|
V
|
IEC 60112 |
Flammability |
Nominal Value
|
Unit
|
Test Method
|
Flame Rating
|
UL 94 | ||
0.75 mm
|
HB
|
||
3.0 mm
|
HB
|
||
Glow Wire Flammability Index (1.0 mm)
|
750
|
°C
|
IEC 60695-2-12 |
Fill Analysis |
Nominal Value
|
Unit
|
Test Method
|
Melt Viscosity (260°C, 1500 sec^-1)
|
130
|
Pa·s
|
ISO 11443 |
Additional Information |
Nominal Value
|
Unit
|
Test Method
|
Filler Content
|
30
|
%
|